Simple Loop Generator Principle,Working

Simple Loop Generator Principle

An electrical generator is a machine which converts mechanical energy (or power) into electrical energy (or power).The energy conversion is based on the principle of the production of dynamically (or due to motion) induced e.m.f.whenever a conductor cuts magnetic flux, dynamically induced e.m.f. is produced in it according to Faraday’s Laws of Electromagnetic Induction. This e.m.f. causes a current to flow if the conductor circuit is closed. Hence, two basic essential parts of an electrical dc generator are (i) a magnetic field and (ii) a conductor or conductors which can so move as to cut the flux.


Simple Loop Generator Construction

In Fig.is shown a single-turn rectangular copper coil ABCD rotating about its own axis in a magnetic field provided by either permanent magnet is or electromagnets. The two ends of the coil are joined to two slip-rings ‘a’ and ‘b’ which are insulated from each other and from the central shaft. Two collecting brushes (of carbon or copper) press against the slip-rings. Their function is to collect the current induced in the coil and to convey it to the external load resistance R. The rotating coil may be called ‘armature’ and the magnets as ‘field magnets’. 

Fig.0

DC Generator Working:

Imagine the coil to be rotating in clock-wise direction (Fig.1). As the coil assumes successive positions in the field, the flux linked with it changes. Hence, an e.m.f. is induced in it which is proportional to the rate of change of flux linkages (e = NdΦdt). When the plane of the coil is at right angles to lines of flux i.e. when it is in position, 1, then flux linked with the coil is maximum but rate of change of flux linkages is minimum. It is so because in this position, the coil sides AB and CD do not cut or shear the flux, rather they slide along them i.e. they move parallel to them. Hence, there is no induced e.m.f. in the coil. Let us take this no-e.m.f. or vertical position of the coil as the starting position. The angle of rotation or time will be measured from this position.



Fig.1

As the coil continues rotating further, the rate of change of flux linkages (and hence induced e.m.f. in it) increases, till position 3 is reached where θ = 90º. Here, the coil plane is horizontal i.e. parallel to the lines of flux. As seen, the flux linked with the coil is minimum but rate of change of flux linkages is maximum. Hence, maximum e.m.f. is induced in the coil when in this position
(Fig.1).

In the next quarter revolution i.e. from 90º to 180º, the flux linked with the coil gradually increases but the rate of change of flux linkages decreases. Hence, the induced e.m.f. decreases gradually till in position 5 of the coil, it is reduced to zero value. So, we find that in the first half revolution of the coil, no (or minimum) e.m.f. is induced in it when in position 1, maximum when in position 3 and no e.m.f. when in position 5. The direction of
this induced e.m.f. can be found by applying Fleming’s Right-hand rule which gives its direction from A to B and C to D. Hence, the direction of current flow is ABMLCD (Fig.0). The current through the load resistance R flows from M to L during the first half revolution of the coil.

In the next half revolution i.e. from 180º to 360º, the variations in the magnitude of e.m.f. are similar to those in the first half revolution. Its value is maximum when coil is in position 7 and minimum when in position 1. But it will be found that the direction of the induced current is from D to C and B to A as shown in Fig.1. Hence, the path of current flow is along DCLMBA which is just the reverse of the previous direction of flow. Therefore, we find that the current which we obtain from such a simple generator reverses its direction after every half revolution. Such a current undergoing periodic reversals is known as alternating current. It is, obviously, different from a direct current which continuously flows in one and the same direction.

It should be noted that alternating current not only reverses its direction, it does not even keep its magnitude constant while flowing in any one direction. The two half-cycles may be called positive and negative half-cycles respectively (Fig.1). For making the flow of current unidirectional in the external circuit, the slip-rings are replaced by split-rings (Fig.2). The split-rings are made out of a conducting cylinder which is cut into two halves or segments insulated from each other by a thin sheet of mica or some other insulating material (Fig.2).

(Fig.2)

As before, the coil ends are joined to these segments on which rest the carbon or copper brushes. It is seen [Fig.(a)] that in the first half revolution current flows along (ABMNLCD) i.e. the brush No. 1 in contact with segment ‘a’ acts as the positive end of the supply and ‘b’ as the negative end. In the next half revolution [Fig.(b)], the direction of the induced current in the coil has reversed. But at the same time, the positions of segments ‘a’ and ‘b’ have also reversed with the result that brush No. 1 comes in touch with the segment which is positive i.e. segment ‘b’ in this case. Hence, current in the load resistance again flows from M to L. The waveform of the current through the external circuit is as shown in Fig.. This current is unidirectional but not continuous like pure direct current.


Fig.3

It should be noted that the position of brushes is so arranged that the change over of segments ‘a’ and ‘b’ from one brush to the other takes place when the plane of the rotating coil is at right angles to the plane of the lines of flux. It is so because in that position, the induced e.m.f. in the coil is zero. Another important point worth remembering is that even now the current induced in the coil sides is alternating as before. It is only due to the rectifying action of the split-rings (also called commutator) that it becomes unidirectional in the external circuit. Hence, it should be clearly understood that even in the armature of a d.c. generator, the induced voltage is alternating.

Share:

Monday, August 3, 2015

Brake Test on DC Shunt Motor:Efficiency By Direct Loading

In this method, the d.c. machine is loaded and output and input are measured to find the efficiency. For this purpose, two simple methods can be used.

Brake test on dc machine:-

In this method, a brake is applied to a water-cooled pulley mounted on the motor shaft as shown in Fig.(6.1). One end of the rope is fixed to the floor via a spring balance S and a known mass is suspended at the other end. If the spring balance reading is S kg-Wt and the suspended mass has a weight of W kg-Wt,then,


Net pull on the rope = (W - S) kg-Wt = (W - S)*9.81 newtons
If r is the radius of the pulley in metres, then the shaft torque Tsh developed by

the motor is


Tsh = (W - S)*9.81*r N - m


If the speed of the pulley is N r.p.m., then,


Let V = Supply voltage in volts
I = Current taken by the motor in amperes
Input to motor = V I watts

(ii) In another method, the motor drives a calibrated generator i.e. one whose efficiency is known at all loads. The output of the generator is measured with the help of an ammeter and voltmeter.


Output of motor =Generator output/Generator efficiency.


Let V = Supply voltage is volts
I = Current taken by the motor is amperes
Input to motor = VI
Thus efficiency of the motor can be determined.
Because of several disadvantages (See Sec. 6.1), direct loading method is used

only for determining the efficiency of small machines.

Tags:theory of brake test on dc shunt motor,brake test on dc compound motor,break test on dc shunt motor,break test on dc shunt motor theory,dc motor evaluation,brake test on dc shunt motor viva
Share:

Wednesday, July 15, 2015

E.M.F. Equation of a D.C. Generator

We shall now derive an expression for the e.m.f. generated in a d.c. generator.
Let Ø= flux/pole in Wb
Z = total number of armature conductors
P = number of poles
A = number of parallel paths = 2 ... for wave winding
= P ... for lap winding
N = speed of armature in r.p.m.
Eg = e.m.f. of the generator = e.m.f./parallel path
Flux cut by one conductor in one revolution of the armature,
dØ = PØ webers
Time taken to complete one revolution,
dt = 60/N second
e.m.f generated/conductor = dØ/dt=PØ/{60/N}=PØN/60

e.m.f. equation of generator

Eg = e.m.f. per parallel path= (e.m.f/conductor) ´ No. of conductors in series per parallel path.

Eg=PØN/60*(Z/A)

 Also Read:
  EMF Equation of Transformer 
  How Does DC Generator Works?
  Unseen DC Windings     
Search:e.m.f. equation of generator pdf,e.m.f. equation of generator derivation,e.m.f. equation of generator easy way ,emf of dc generator. 
Share:

D.C. Machine Armature Windings

D.C. Machine Armature Windings

The different armature coils in a d.c. armature winding must be connected in series with each other by means of end connections (back connection and front connection) in a manner so that the generated voltages of the respective coils will aid each other in the production of the terminal e.m.f. of the winding.This windings are same in both DC motor and DC generator.

Two basic methods of making these end connections are:

1. Simplex lap winding.
2. Simplex wave winding.

1. Simplex lap winding.

lap winding diagram

For a simplex lap winding, the commutator pitch YC = 1 and coil span YS ~ pole pitch. Thus the ends of any coil are brought out to adjacent commutator segments and the result of this method of connection is that all the coils of the armature .ire in sequence with the last coil connected to the first coil.Consequently, closed circuit winding results. This is illustrated in Fig. where a part of the lap winding is shown. Only two coils are shown for simplicity. The name lap comes from the way in which successive coils overlap the preceding one.

2. Simplex wave winding

wave winding diagram
For a simplex wave winding, the commutator pitch YC ~ 2 pole pitches and coil span = pole pitch. The result is that the coils under consecutive pole pairs will be joined together in series thereby adding together their e.m.f.s [See Fig. 1.22].After passing once around the armature, the winding falls in a slot to the left or right of the starting point and thus connecting up another circuit. Continuing in this way, all the conductors will be connected in a single closed winding. This winding is called wave winding from the appearance (wavy) of the end connections.

Above we discussed difference between lap winding and wave winding briefly.

Search Terms: dc machine armature winding,dc motor armature winding pdf,dc motor armature winding diagram,dc motor armature winding animation

Share:

Wednesday, July 8, 2015

DC Generator : Working,Principle

DC Generator : Working,Principle 

An electrical generator is a machine which converts mechanical energy (or power) into electrical energy (or power).DC generator works on the principle of Faraday's Laws of Electromagnetic Induction.

Faraday's Laws of Electromagnetic Induction:

According faraday's laws whenever a conductor cuts magnetic flux. dynamically induced e.m.f. is produced in it.this e.m.f. causes a current to flow if the conductor circuit is closed.energy conversion in the generator is based on the principle of the production of dynamically (or motionally) induced e.m.f in armature.

the amount of emf generated is 
E=dφ/dt

We have two basic essential parts of an DC generator are 
i) a magnetic field and (ii) a conductor or conductors which can so move as to cut the flux. 

DC Generator Working Principle:

Working principle of dc generator can be explained with single loop generator concept.let us consider single loop coil inserted in magnetic (N-S)field as shown in the figure.assign loop edges with ABCD as marked..the magnetic field direction will be from N-S.assume you are rotating the coil
Step1:-


In this mode the dφ is maximum,because AB and CD are parallel to magnetic filed direction.field strength at CD and AB are not same so dφ exist.the out put voltage we E=dφ/dt.the current direction will be given by  current can be determined by Flemming's right hand Rule. This rule says that is you stretch thumb, index finger and middle finger of your right hand perpendicular to each other, then thumbs indicates the direction of motion of the conductor, index finger indicates the direction of magnetic field,from Flemming's right hand Rule current flow from A to B ,C to D.
 Step2:-


In this mode the dφ is minimum,because AB and CD are perpendicular to magnetic filed direction.field strength at CD and AB are same so dφ almost zero.hence we assume current is also zero.
Step3:-


In this mode the dφ is maximum,because AB and CD are parallel to magnetic filed direction.field strength at CD and AB are not same so dφ exist.the out put voltage we E=dφ/dt.the current direction will be given by  current can be determined by Flemming's right hand Rule. Flemming's right hand Rule current flow from B to A ,D to C.

ALL DONE..but observe Step1 and Step3 we are getting AC in DC generator instead of DC to eliminate bi directional current we use slip rings.by using slip ring we convert bi directional current into uni directional current.Split ring are made out of a conducting cylinder which cuts into two halves or segments insulated from each other. The external load terminals are connected with two carbon brushes which are rest on these split slip ring segments.

DC Generator with slip rings:

DC Generator output waveform:



This is basic working principle of DC generator,explained by single loop generator model.


An Awesome Video Tutorial On DC Generator:



Share:

Recent Posts

Unordered List

Definition List